NEC Univerge sv8500 Manual page 632

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

9.
Setting Fax sender PAD value:
MC-MG> SET FAXSENDPAD_MG 3
Fax Sender PAD setting succeeded.
The FAXSENDPAD command assigns the value to decrease the Fax signal level in the sender (IP to PSTN)
Note:
direction when Fax signal is detected.
The total PAD value (Sender PAD + Fax Sender PAD) is limited to 20dB.
Note:
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
10. Setting I/C call abandon timer:
MC-MG > SET IC_ABANDON_TIME 0
I/C Call Abandon Timer setting succeeded.
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
MCMG [SCA-4LC2COTA/MG-4LC2COTA]
Line 1: Enter the Fax Sender PAD value in the range of 0-
20 after the command name (default=3)
Line 2: Result is shown
Line 1: Enter the Incoming call abandon timer (0-2)
0=6 seconds (default)
1=3 seconds
2=1 second
Line 2: Result is shown