NEC Univerge sv8500 Manual page 735

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

12. Setting DSP smooth PAD mode:
MC-MG > SET SMOOTH_PAD_MG 3
Smooth PAD Model setting succeeded.
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
13. Setting RVS mode (for Australia):
MC-MG > SET RVS_AUST
Reverse Watch (ROA/ROS): ROA
Reverse Watch (AU) setting succeeded.
14. Setting Auto Polarity
MC-MG > SET AUTO_POLARITY OFF
Auto Polarity setting succeeded.
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
Line 1: Enter a value of smooth PAD(1-5, OFF).
OFF=Set smooth PAD mode to OFF
1=+2.0dBm (default)
2=-5.2dBm
3=-2.1dBm
4=-0dBm
5=-4.2dBm
Line 2: Result is shown.
Line 1:
Line 2: Enter RVS mode
ROA = Reversal on Answer (default)
ROS = Reversal on Seizure
Line 3: Result is shown
Line 1: Specify the auto polarity
OFF=Invalid (default)
ON=Valid
Line 2: Result is shown
VOL.2-482
MCMG Card [SCA-7COTA]

Hide quick links:

Advertisement

Table of Contents
loading