Make sure that a new firmware has been installed by checking the following:
STEP 19
->dispver
Boot program version
Main program version
|
|---TC version
|---DSP kernel version
|---DSP program version
|---Tone version
Enter "show config" to confirm the config data.
STEP 20
<Confirmation of MG(PRI)>
Connect the MG(PRI) to a network.
STEP 21
To confirm MG(PRI) is properly operating with the upgraded firmware, make a call to the
STEP 22
MG(PRI). Check that you can hear RBT.
Receive a call via the MG(PRI), and confirm that you can talk to each other.
STEP 23
After all the tasks are completed, write down/label the firmware version in the back of the
STEP 24
MG(PRI). For example, 2A is indicated for Version 2. 3A is indicated for Version 3.
MG(PRI) (1.5M) [SCA-24PRIA/MG-24PRIA]
Boot Number
SP3839 SH7751R CBOOT-1 PROG-A [03.00.00.00]
Main Name
SP3884 MG PRI PROG-A [05.00.00.00]
TC-Program
DSP-K-AC49kernel
DSP-P-AC490012ae3-S
Tone version
VOL.2-1074
Boot Issue
Main Issue
[04.00.00.00]
[01.07.06.00]
[01.07.08.02]
[04.00.00.00]