Set Command (Mg Side) - NEC Univerge sv8500 Manual

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

SET COMMAND (MG side)

1.
Setting CAR Detection
MC-MG> SET CAR_DETECT OFF
CAR Detecting setting succeeded.
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
2.
Setting CODEC Coefficiency:
MC-MG > SET CODEC_COEF_MG 0 2
CODEC Coefficient (CH00) setting succeeded.
The setting values are shown in the following table. Setting value "2" is assigned when the product is
Note 1:
shipped. Change the data if required.
North America
RESISTER
600Ω+2.16μF
600Ω+2.16μF
600Ω+2.16μF
600Ω+2.16μF
600Ω+2.16μF
600Ω+2.16μF
Australia
RESISTER
220Ω+(820Ω//120nF)
220Ω+(820Ω//120nF)
600Ω
Line 1: Select the Number Detection
OFF=Invalid (default)
ON=Valid
Line 2: Result is shown
Line 1: Enter the Line Number 0-3. And then, enter
the setting value (default is 2) after the space.
Line 2: Result is shown
KIND OF BNW
600Ω+2.16μF
600Ω
350Ω+(1000Ω//210nF)
900Ω+2.16μF
900Ω
800Ω//(100Ω+50nF)
KIND OF BNW
220Ω+(820Ω//120nF)
600Ω
600Ω
VOL.2-275
MC & MG with PFT
SETTING VALUE
0 (default)
1
2
3
4
5
SETTING VALUE
0 (default)
1
2

Hide quick links: