NEC Univerge sv8500 Manual page 1203

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

<CONDITIONS CHECK >
Make sure that PWR lamp lights on
STEP 1
Make sure that LINK lamp lights on
STEP 2
Make sure that ON LINE lamp lights on
STEP 3
Make sure that LAYER 2 lamp lights on
STEP 4
Make sure the signaling via MG-PRI/PRA is normal
STEP 5
Make sure the MG-PRI/PRA is working properly.
STEP 6
13.3.4 Detailed Procedure
The following explains the detailed procedures. The procedures are divided into three parts: MG-PRI/PRA set-
ting, Telephony Server setting, and Connection Check. These steps provide the necessary data only for MG-
PRI/PRA setup. Attributes in this section are explained using some signs in the following:
"DRS (Device Registration Server)" used in this section refers to the Telephony Server. The Telephony
Note:
Server acts as DRS for MG-PRI/PRA using Proprietary Protocol.
EXAMPLE
STEPx: Specify System Data
INDEX 810 = 1
INDEX 810 : Specify the XX Data.
If you need more information about these commands, refer to
PRA console commands, or Command Manual.
MG-PRI/PRA Settings
This item describes the procedures for MG-PRI/PRA by using the Maintenance Console, which connects to
MG-PRI/PRA. For more information, refer to
Specify IP Addresses of DRS and Default Gateway
STEP 1
About IP address of DRS (Telephony Server), refer to "Registration Destination of IP Devices/Stations" in
Note 1:
INTRODUCTION of Installation Manual.
Specify whether to use DHCP by using SET DHCP command.
When using DHCP server
If the setting is specified for the first time, because DHCP server is enabled as default setting, it is not
necessary to perform the following.
Equal Sign (=) shows a determined attribute for the MG-PRI/PRA setup
Colon (:) shows an attribute required for user selection.
13.4 Operation and
Note 1
VOL.2-950
13.4 Operation and Maintenance
Maintenance.
MG-PRI/PRA
for MG-PRI/

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents