NEC Univerge sv8500 Manual page 1280

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

Check the availability if MG is connected to the following equipment by tandem connection.
CONNECTING EQUIPMENT
MC Note 1
COT Note 2
LDT Note 2
4W ODT
PRI/BRI
EC enabled
TDM64K
EC disabled
EC enabled
TDM32K
EC disabled
TDM Less Than 32K
- : Not guaranteed
: Available
Tandem here stands for a connection that is established over multiple networks such as shown in the fol-
Note 1:
lowing figure.
Connection between STN A and STN B cannot be guaranteed.
STN A
Tandem Connection Availability
AVAIL-
ABILITY
Not recommended because
-Voice quality may be degraded due to multiple conversion.
-Delay may be increased due to excessive jitter buffer insertion.
Voice speech and FAX relay are available. However, DTMF relay is not
guaranteed. (Input level can be lower than minimum DTMF detection
level -27.0 dBm because of line loss at public network side.)
Design your private network so that DTMF input level at MG(PRI) may
be larger than -27.0 dBm. If not DTMF relay is not guaranteed.
Not recommended because voice quality may be degraded due to data
conversion.
ISDN
MG
MG(PRI) (1.5M) [SCA-24PRIA/MG-24PRIA]
DESCRIPTION
IP Network
VOL.2-1027
MC
STN B

Hide quick links:

Advertisement

Table of Contents
loading