NEC Univerge sv8500 Manual page 1318

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

14.4 Operation and Maintenance
This section explains the operation and maintenance procedure of MG(PRI). Configuration data is assigned by
using Maintenance Console (PC).
14.4.1 How to Back Up And Restore Config Data by Serial Connection (Local Download)
This config download/upload is performed one by one, connecting a PC to each MG(PRI) with a Con-
sole Cable (RS232C <-> RJ-45) and a LAN cable. Prepare the following:
- Console Cable (RS232C <-> RJ-45) cable is required.
- Serial terminal emulation program (such as HyperTerminal) is required
- LAN cable (crossover) is required for restoring config data.
- PCPro has to be installed in advance.
Backing Up Config Data By Serial Connection
Configdata
Serial Console
Power off MG(PRI) and disconnect it from the network.
STEP 1
Connect PC to MG(PRI) by using Console Cable (RS232C <-> RJ-45) cable.
STEP 2
Power on MG(PRI).
STEP 3
Activate HyperTerminal and set the following:
STEP 4
Bit per second:9600bps
Data bits:8bit
Parity:None
Stop bit:1bit
Flow control:None
Select [Transfer] -> [Capture File...].
STEP 5
Send File screen is displayed. Specify a file name to be saved, and then click the Start button.
STEP 6
After a prompt (->) is displayed, enter "usrConsole".
STEP 7
After a prompt (">MG-PRI" or ">MG-PRI(SIP)") is displayed, enter "show config" to
STEP 8
display configuration data of the MG(PRI).
Select [Transfer] -> [Capture Text] -> [Stop] to save the config file shown in screen.
STEP 9
MG(PRI) (1.5M) [SCA-24PRIA/MG-24PRIA]
Console Cable
PWR
ALM
VOL.2-1065
100M LINK
B
D
CONSOLE
ON
MUSIC
RESET
LINE LB
Ether
LINE
MG(PRI)