- Confirm MG-BRI SIP is displayed in Firmware File Name. If it is not in the list, create an
item by clicking the Insert button. Set the following attributes, and then click the OK button.
After completing the above, click the Insert button located in Terminal Information.
Select Specify Terminal Type in How to Specify Terminal, and then select "BRI MG".
STEP 6
Click the Search button.
STEP 7
After the MG-BRIs are displayed in Result of Search, select the appropriate MG-BRI to be
STEP 8
upgraded the firmware.
If you narrow them down by specifying Terminal Type in the ATDL command, MG-BRIs will be displayed
Note:
per registered channel. Therefore, when multiple channels are registered in an MG-BRI, in the box, the
same MG-BRI is displayed more than once. To avoid setting upgrade task to the target MG-BRI more then
once, select either one of the channels used in the MG-BRI by checking LENS.
Click the Add to the Terminal List button to go back to the main screen.
STEP 9
Click the Exe button to upgrade the firmware to the target MG-BRIs.
STEP 10
"Upgrade is succeeded" is displayed. Note that version information in the screen is not up-
dated at this time. If the upgrade is failed, click the Close button, and then go back to STEP3.
Although whether or not download process is completed, the MG-BRI automatically restarts.
Note:
After upgrade is completed, click the Close button on the status window. In the main screen,
STEP 11
click the Exit button to close the ATDL command.
To confirm the firmware, activate the DIPI command.
STEP 12
Select "ISDN Trunk (BRI)" in "Media Gateway", and then click the Execute button.
STEP 13
Confirm that the firmwares in the appropriate ones are upgraded.
STEP 14
The issue of the file in the screen is indicated as follows:
01.00.00.00
ISSUE NUMBER (ISSUE 1.0)
VOL.2-764
MG-BRI