SYS1, INDEX 811
Assign the Tone Code by countries. For more information, refer to the Command Manual.
SYS1, INDEX 813
Assign the PAD value of MC
00 = No PAD control (conforms to the setting on ASYD, SYS1, INDEX 4, b5)
01 = PAD OFF (0dB)
02 = 3dB
03 = 6dB
AUNT: Assignment of Unit Data
MG: Module Group Number
TYPE: 1 (Select 1 for Unit data assignment)
UNIT0: 1/2 (Unit 0 is used/not used).
UNIT1: 1/2 (Unit 1 is used/not used).
UNIT2: 1/2 (Unit 2 is used/not used).
UNIT3: 1/2 (Unit 3 is used/not used).
ANPD: Assignment of Numbering Plan
1st DC: Assign the 1st DC of the station numbers.
NND: Assign the total station number digits.
ASPA: Assignment of Special Access Code
ACC: Assign the Access Code using the 1st DC specified by the ANPD command.
ATNR: Assignment of Tenant Restriction Class Data
Assign the Connection Restriction Data between Originating Tenant (OGTN) and Terminating Tenant
(TMTN). When ASYD, SYS1, INDEX 94, b0=0 is assigned (Multiple Tenant Service is in-service), assign
the respective Tenant Number of OGTN and TMTN. If not (when the data is "1"), assign the fixed Tenant
Number of "1" for both OGTN and TMTN.
TRI:
"0" for Station-to-Station Calling
OGTN: Number of Originating Tenant
TMTN: Number of Terminating Tenant
RES:
"0" for restriction/"1" for permission
For a Station-to-Outgoing Trunk Connection, allow the Route Restriction for each trunk by the ARSC com-
Note:
mand.
MCMG [SCA-4LC2COTA/MG-4LC2COTA]
VOL.2-331