After a prompt (->) is displayed, enter "usrConsole".
STEP 9
After a prompt (">MG-PRI" or ">MG-PRI(SIP)") is displayed, enter "get configda-
STEP 10
ta <TFTP's IP Address>" to download configuration data into MG(PRI).
Confirm that "successfully completed" is displayed in the command prompt, indicating the
STEP 11
upload to TFTP server is completed normally.
To reflect the configuration data that is downloaded from TFTP server, save it by entering
STEP 12
"save config" and reboot MG(PRI) by entering "reboot".
Exit the HyperTerminal by selecting [File] -> [Exit].
STEP 13
<Confirmation of MG(PRI)>
Confirm that MG(PRI) is normally registered in system after reboot. Use the DISD/FPTS
STEP 14
commands. For more information, refer to the Command Manual.
Check that calls via MG(PRI) can be made.
STEP 15
MG(PRI) (1.5M) [SCA-24PRIA/MG-24PRIA]