27. SET
TCS_T1_2
This command is used to specify T1 data. To make this assignment effective, it is required to execute the
"SAVE" command and to restart before exiting the maintenance command.
COMMAND 1
MG-PRI > SET TCS_T1_2
Remote Alarm
Alarm Operation Mode
(AIS Remote Alarm Sending)( 0/1:0 ): 0
Alarm Release Timing
Alarm Detect/Release Type ( 0/1:0 ): 0
Line Signal
Multi Frame
Signaling In Channel
Dch Mode
Equalizer
set value is 0x0000
setting complete.
In order to make a setup reflect, re-starting
is required after saving a configuration file
by SAVE command.
COMMAND 2
MG-PRI > SET TCS_T1_2 0000
set value is 0x0000
setting complete.
In order to make a setup reflect, re-starting
is required after saving a configuration file
by SAVE command.
[P1]
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0-4:0 ): 0
VOL.2-988
P1-Specify a set value
0000-FFFF= Set value (default value: 0000)
When P1 is omitted→COMMAND 1
When P1 and P2 are specified→COMMAND 2
<COMMAND 1>
1) Specify Remote Alarm
0=Data Link, Fs bit (default)
1=In Channel
2) Enable/Disable Alarm Operation Mode
0/1=Enable (default)/Disable
3) Specify Alarm Release Timing
0=Short (default)
1=Long
4) Specify Alarm Detect/Release Type
0=Normal (default)
1=AT&T
5) Specify Line Signal
0=Binary 8 Zero Substitution (B8ZS) (default)
1=Alternate Mark Inversion with Zero Code
Suppression (AMI ZCS)
6) Specify Multi Frame
0=24 Multi Frame (default)
1=12 Multi Frame
7) Specify Signaling in Channels
0 (fixed)
8) Specify Dch Mode
0=ITU-T (default)
1=AT&T
9) Specify Equalizer
0=0-40m (default)
1=41-80m
2=81-121m
3=122-161m
4=162m or more