10.3.6 Basic Test Procedures
[1] Basic Connection Test
START
1. Is the PWR Lamp lighting green?
NO
Is the Power Cable firmly connected?
YES
2. Is the LINK Lamp lighting green?
NO
The MG-COT may not be physically connected to the LAN. Check the LAN Cable between the MG-COT
and Network Device.
Use a LAN Cable (straight-through).
YES
Test the continuity in the LAN Cable.
Make sure the network device (SW HUB or Router) is turned ON.
If the problem is not cleared, change the LAN Cable or change the network device.
*Initial setting on MG-COT is started.
*Registration established.
*Initial setting between MG-COT and MGC (Telephony Server) is started.
*MG-COT starts operating normally.
3. Is the ON LINE Lamp lights green?
NO
Confirm the data setting of MGC (Telephony Server) and MG-COT.
MGC: Confirm the data setting of ASYD, ASYDL, ALOCL, ADTM, ALIDL, ARTD, ARTI, ATRK, AMGIL,
and AMGVL.
YES
MGC: Confirm the data setting of ALIDL and AISTL.
MG-COT: Check configuration data assigned by maintenance console.
A
VOL.2-674
MG-COT Card [SCA-6COTB]