22. SET
TCS_E1_2
This command is used to specify E1 data. To make this assignment effective, it is required to execute the
"SAVE" command and to restart before exiting the maintenance command.
COMMAND 1
MG-PRI > SET TCS_E1_2
Multi-frame Remote Alarm ( 0/1:0 ): 0
Alarm Release Timing
Line Signal
CRC4
DTI Mode
CRC Multi-frame Format
Ebit Automatic Sending
TS16 Control
Dch Mode
Loop Back Pattern
Alarm Detect/Release Type (0/1:0): 0
set value is 0x1000
setting complete.
In order to make a setup reflect, re-starting
is required after saving a configuration file
by SAVE command.
COMMAND 2
MG-PRI > SET TCS_E1_2 1000
set value is 0x1000
setting complete.
In order to make a setup reflect, re-starting
is required after saving a configuration file
by SAVE command.
[P1]
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0/1:1 ): 1
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0/1:0): 0
( 0/1:0 ): 0
VOL.2-981
P1-Specify a set value
0000-FFFF= Set value (default value: 1000)
When P1 is omitted→COMMAND 1
When P1 is specified→COMMAND 2
<COMMAND 1>
1) Enable/Disable Multi-frame Remote Alarm
0/1=Enable(default)/Disable
2) Specify Alarm Release Timing
0=Short (default)
1=Long
3) Specify Line Signal
0=HDB3 (default)
1=AMI
4) Enable/Disable CRC4
0/1=Disable/Enable (default)
5) Specify DTI Mode
0 (fixed)
6) Enable/Disable CRC Multi-frame Format
0/1=Disable (default)/Enable
7) Enable/Disable Ebit Automatic Sending
0 (fixed)
8) Specify Time Slot 16 Control
0=Data Through (default)
1=Signaling
9) Specify Dch Mode
0=ITU-T (default)
1=AT&T
10) Specify Loop Back Pattern
0 (fixed)
11) Specify Alarm Detect/Release Type
0=ETSI (default)
1= ITU-T
A command is executed, and the result is displayed. On
screen, the settings are set to in FCE0 (setting value).
<COMMAND 2>
A command is executed, and the result is displayed.
MG-PRI/PRA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents