KIND2: Specify the PAD value of Analog MC in the range of 0-3.
KIND3: Specify the PAD No. of IPPAD in the range of 0-15.
Setting of Echo Canceller: Click the check box to assign the Echo Canceller data, and select one of the ra-
When the same value is assigned to both "A LOC-ID" and "B LOC-ID" parameters, select either "A EC-
Note:
ON/B EC-ON" or "A EC-OFF/B EC-OFF."
MC-MG needs to be rebooted after station data is assigned to reflect change. Confirm that there is no con-
Note:
versation in progress when rebooting.
•No PAD control (determined by ASYD, SYS1, INDEX 4, bit5 (5 dB PAD))
•PAD OFF (0 dB)
•3 dB
•6 dB
PAD value is determined by this PAD No. (0-15) and the setting of SW10-6/7 on IPPAD
card. Refer to the Circuit Card Description for more details.
dio buttons.
•A EC-ON/B EC-ON
•A EC-ON/B EC-OFF
•A EC-OFF/B EC-ON
•A EC-OFF/B EC-OFF