12.3.6 Basic Test Procedures
Operation of MG(BRI) can be checked from the visual inspection of lamp display (see
in section 12.1.3 on page
[1] Basic Connection Test
STEP 1: Is the PWR lamp lighting green?
[No]
Check the AC power cable is firmly inserted.
Check the PWR switch is ON.
Check the AC power cable from the AC power inlet is firmly connected to power source.
[Lights green]
Go on to STEP 2.
STEP 2: Is the LINK lamp lighting green?
[No]
MG(BRI) may not be physically connected to the LAN. Check the LAN cable between MG(BRI)
and networking device. (Also check the power of Switching HUB and Routers are turned ON.)
Check that correct cable is used (Use the Straight-through cable)
Check that the cable is not damaged. (Test the continuity in the LAN cable.)
Replace the LAN cable or the network device if the problem is still not cleared.
[Lights green]
This lamp turns ON when MG(BRI) initially starts up and connection to LAN is established.
Go on to STEP 3.
STEP 3: Is the ON LINE lamp lighting green?
[No]
Check the data assignment of the Telephony Server side and MG(BRI) side.
Telephony Server: Is the data assignment on each PCPro command correct?
MG(BRI): Check the configuration data assigned from the maintenance console.
[Lights green]
Go on to STEP 4.
STEP 4: Is the D lamp of LINE0/1 lamp lighting green?
[No]
789).
VOL.2-836
MG(BRI) [SCA-2BRIA/MG-2BRIA]
Lamps on the Front Panel