Delta ASDA-A3 Series User Manual page 1231

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

Troubleshooting
ALD30 EnDat 2.2 encoder - readiness warning
14
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
ALD31 EnDat 2.2 encoder - diagnostic warning
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
14-84
Condition: an error occurred to the EnDat 2.2 encoder.
Cause:
The installation or wiring of the encoder is incorrect.
1.
The installation and operating environment do not meet the specifications,
2.
causing encoder error.
The encoder is damaged.
3.
Make sure the encoder or read head is correctly installed and wired according
1.
to the manufacturer's instruction manual.
If the issue persists, contact the distributor of the encoder.
2.
DI.ARST
Condition: an error occurred to the EnDat 2.2 encoder.
Cause:
The installation or wiring of the encoder is incorrect.
1.
The installation and operating environment do not meet the specifications,
2.
causing encoder error.
The encoder is damaged.
3.
Make sure the encoder or read head is correctly installed and wired according
1.
to the manufacturer's instruction manual.
If the issue persists, contact the distributor of the encoder.
2.
DI.ARST