Avaya S8700 Maintenance Manual page 2116

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-567. TEST #759 Configuration Audit — Continued
Error
Test
Code
Result
Description / Recommendation
102
FAIL
The SNC circuit pack cannot communicate with the SNI in slot 2.
1. If a standby SNC (one with its yellow LED off) was tested and resulted in
2. Use list configuration carrier to determine whether an SNI is physically
3. Display errors for category pnc. If the SNC has SNC-BD error 513, or
4. If SNIs in the same carrier have SNI-BD error 257 logged, (indicating they
5. If the SNC being tested has SNC-LINK error type 1, replace the SNI in slot
6. If the SNC being tested still has SNC-LINK error type 1, replace the SNC
8-1394
Issue 1 May 2002
this error code, follow normal escalation procedures. (status switch-node
will also display the active and standby SNCs.)
present in slot 2. If the
Vintage
present, proceed to step 3. If the
one of the following:
If an SNI is not supposed to be installed in slot 2:
a. This failure will not affect service. The missing SNI can be removed
from administration with change circuit-pack.
b. If the error persists, reset the active SNC circuit pack with reset board
UUCSS. If the error still persists, replace the active SNC circuit pack.
If an SNI is supposed to be installed in slot 2, insert one.
SNC-LINK errors with aux data 1 pointing to other SNIs besides the one in
slot 2, replace the active SNC circuit pack.
are having trouble communicating with the SNC), replace the active SNC
circuit pack.
2. Replacing an SNI may interrupt service. See
Pack)'' on page 8-1429
for the procedure for replacing an SNI.
circuit pack.
field indicates that a circuit pack is
Vintage
field reports
no board
''SNI-BD (SNI Circuit
Continued on next page
, do
555-233-143

Advertisement

Table of Contents
loading

Table of Contents