Maintenance-Object Repair Procedures
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Configuration audit (#759), you may also clear errors generated from other tests
in the testing sequence.
Order of Investigation
Configuration audit (#759)
Failure audit (#777)
Processor Route audit (#760)
SNC On-Board test (#778)
TPN test (#779)
Switch Node Clock Reset test (#780)
1.
D = Destructive, ND = Nondestructive
NOTE:
Test #983 is not an actual demand maintenance test. This test number is
used to report results of executing of the clear firmware-counters
command. Refer to error codes for Test #777.
Configuration Audit (#759)
This test is nondestructive.
This test is run via the test board short or test board long command for SNC
circuit packs.
For SNC circuit packs, this test queries the SNC for SNCs and SNIs in the same
switch node carrier that the SNC can communicate with and compares this data to
the administered data.
Failures of this test cause entries in the error and alarm logs against Switch Node
Configuration (SN-CONF) with the board location of the SNC.
8-1392
Issue 1 May 2002
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
Reset Board
1
Sequence
D/ND
ND
ND
ND
ND
ND
X
D