Maintenance-Object Repair Procedures
Table 8-567. TEST #759 Configuration Audit — Continued
Error
Test
Code
Result
Description / Recommendation
112
FAIL
The SNC circuit pack cannot communicate with the other SNC.
If this test was run on the active SNC and if the switch node carrier is
administered with duplicate SNCs:
1. If the system originally had duplicate SNCs and the standby SNC was
2. Check the error log via display errors. If SNIs in the switch node carrier
3. Replace the standby SNC circuit pack.
4. Retry the test board command. If this test continues to fail, replace the
If this test was run on the active SNC and if the switch node carrier is
administered with only one SNC:
1. Replace the SNC.
112
FAIL
If this test was run on the standby SNC:
(cont'd)
1. Check the error log via display errors. If more than one SNI in the switch
2. Replace the standby SNC circuit pack.
3. Retry the test board command. Check the error log via display errors. If
8-1402
Issue 1 May 2002
removed and never replaced, this error will occur. If you do not intend to
replace the SNC:
a. Remove the standby SNC from circuit pack administration via change
circuit-pack.
b. If the problem persists, reset the active SNC circuit pack via reset
board UUCSS. If the problem persists after the reset, replace the
active SNC circuit pack.
also have problems communicating with the active SNC (i.e., error code
257 is logged against SNI-BD), then replace the active SNC.
active SNC.
node carrier has problems communicating with the active SNC (i.e., error
code 257 is logged against SNI-BD), then replace the active SNC.
this error is still in the error log, replace the active SNC.