S-SYN-PT (Speech Synthesis Port)
Table 8-560. TEST #165 Speech Synthesis DSP Tone Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call and therefore unavailable for certain tests. Wait until the
port is idle (amber LED is off) before retesting.
1. If the port is idle retry the command at 1-minute intervals up to 5 times.
1001
ABORT
System resources required to run this test are not available.
1002
1. Retry the command at 1-minute intervals up to 5 times.
1003
1021
ABORT
The 440-Hz tone was not detected by the Tone Detector circuit and inter-digit
time-out has occurred on the Tone Detector circuit.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, verify that every Tone Detector circuit in the
3. If the test continues to abort, replace the Speech Synthesis circuit pack.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The 440-Hz tone was not detected by the Tone Detector circuits.
1. If the test fails again, verify that every Tone Detector circuit in the system is
2. If the test fails again, replace the Speech Synthesis circuit pack.
PASS
The 440-Hz tone has been detected correctly. User-reported troubles should
be investigated using other tests and by verifying other ports on this circuit pack
are working correctly.
555-233-143
system is functioning correctly by checking the Error Log and using the
test board UUCSS long command. Replace any faulty circuit packs
containingTone Detector circuits, and repeat the test.
functioning correctly by checking the Error Log and using the test board
UUCSS long command. Replace any circuit packs containing faulty Tone
Detector circuits, and repeat the test.
Continued on next page