Synchronous Operation; Figure 18.10 Example Of Input Capture Operation - Renesas HD6417641 Hardware Manual

32-bit risc microcomputer superh risc engine family / sh7641 series
Table of Contents

Advertisement

Section 18 Multi-Function Timer Pulse Unit (MTU)
TCNT value
H'0180
H'0160
H'0010
H'0005
H'0000
TIOCA
TGRA
TIOCB
TGRB
18.4.2

Synchronous Operation

In synchronous operation, the values in a number of TCNT counters can be rewritten
simultaneously (synchronous presetting). Also, a number of TCNT counters can be cleared
simultaneously by making the appropriate setting in TCR (synchronous clearing).
Synchronous operation enables TGR to be incremented with respect to a single time base.
Channels 0 to 4 can all be designated for synchronous operation.
Rev. 4.00 Sep. 14, 2005 Page 568 of 982
REJ09B0023-0400
H'0005

Figure 18.10 Example of Input Capture Operation

Counter cleared by TIOCB
input (falling edge)
H'0160
H'0180
Time
H'0010