Figure 18.86 Error Occurrence In Normal Mode, Recovery In Pwm Mode 1 - Renesas HD6417641 Hardware Manual

32-bit risc microcomputer superh risc engine family / sh7641 series
Table of Contents

Advertisement

(2)
Operation when Error Occurs during Normal Mode Operation, and Operation is
Restarted in PWM Mode 1
Figure 18.86 shows an explanatory diagram of the case where an error occurs in normal mode and
operation is restarted in PWM mode 1 after re-setting.
1
RESET
TMDR
(normal)
MTU module
output
TIOC*A
TIOC*B
Port output
TIOC*A/PTE[n]
TIOC*B/PTE[n]
n = 0 to 15

Figure 18.86 Error Occurrence in Normal Mode, Recovery in PWM Mode 1

1 to 10 are the same as in figure 18.85.
11. Set PWM mode 1.
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized. If
initialization is required, initialize in normal mode, then switch to PWM mode 1.)
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
2
3
4
5
6
TOER
TIOR
PFC
TSTR
(1)
(1 init
(MTU)
(1)
0 out)
High-Z
High-Z
Section 18 Multi-Function Timer Pulse Unit (MTU)
7
8
9
10
Match
Error
PFC
TSTR
TMDR
occurs
(PORT)
(0)
(PWM1)
Rev. 4.00 Sep. 14, 2005 Page 645 of 982
11
12
13
14
TIOR
PFC
TSTR
(1 init
(MTU)
(1)
0 out)
• Not initialized (TIOC*B)
REJ09B0023-0400

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sh7641

Table of Contents