Section 18 Multi-Function Timer Pulse Unit (MTU)
(23) Operation when Error Occurs during Complementary PWM Mode Operation, and
Operation is Restarted in Complementary PWM Mode
Figure 18.107 shows an explanatory diagram of the case where an error occurs in complementary
PWM mode and operation is restarted in complementary PWM mode after re-setting (when
operation is restarted using the cycle and duty settings at the time the counter was stopped).
1
RESET
TOCR
MTU module
output
TIOC3A
TIOC3B
TIOC3D
Port output
TIOC3A/PTE[7]
TIOC3B/PTE[6]
TIOC3D/PTE[4]
Figure 18.107 Error Occurrence in Complementary PWM Mode, Recovery in
1 to 10 are the same as in figure 18.105.
11. Set MTU output with the PFC.
12. Operation is restarted by TSTR.
13. The complementary PWM waveform is output on compare-match occurrence.
Rev. 4.00 Sep. 14, 2005 Page 666 of 982
REJ09B0023-0400
2
3
4
5
6
TMDR
TOER
PFC
TSTR
(CPWM)
(1)
(MTU)
(1)
High-Z
High-Z
High-Z
Complementary PWM Mode
7
8
9
10
Match
Error
PFC
TSTR
PFC
occurs
(PORT)
(0)
(MTU)
11
12
13
TSTR
Match
(1)