18.6
Operation Timing
18.6.1
Input/Output Timing
TCNT Count Timing: Figure 18.54 shows TCNT count timing in internal clock operation, and
figure 18.55 shows TCNT count timing in external clock operation (normal mode), and figure
18.56 shows TCNT count timing in external clock operation (phase counting mode).
Pφ
Internal clock
TCNT input
clock
TCNT
Figure 18.54 Count Timing in Internal Clock Operation
Pφ
External clock
TCNT input
clock
TCNT
Figure 18.55 Count Timing in External Clock Operation
Falling edge
N-1
N
Falling edge
N-1
N
Section 18 Multi-Function Timer Pulse Unit (MTU)
Rising edge
N+1
Rising edge
Falling edge
N+1
Rev. 4.00 Sep. 14, 2005 Page 619 of 982
N+2
N+2