Avaya S8700 Maintenance Manual page 2135

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

SNC-BD (Switch Node Clock Circuit Pack)
Failure Audit (#777)
This test is nondestructive.
This test queries an SNC for any existing failures and any unacknowledged
"cleared failure" messages. Each failure generates an error and alarm entry
against SNC-BD, SNC-LINK, or SNC-REF. A "cleared failure" message is a
message an SNI circuit pack sends to software indicating the resolution of a
previous failure. This message is "unacknowledged" if the SNI circuit pack never
receives a response from software indicating it's own receipt of the original
"cleared failure" message.
If no failures are detected by the SNC circuit pack, this test will pass.
If this test reports failures, the results screen for the test board command will
show FAIL with no FAIL code. The error log must then be displayed via display
errors with category PNC to view every SNC-related errors: SNC-BD, SNC-LINK,
and SNC-REF.
Table 8-569. TEST #777 Failure Audit
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABORT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABORT
The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
555-233-143
Continued on next page
Issue 1 May 2002
8-1413

Advertisement

Table of Contents
loading

Table of Contents