Regular output

Types of messages

AlliedWare
messages
The following messages are an example of output from AT-8900 and AT-9900
switches.
INFO: Self tests beginning.
INFO: RAM test beginning.
PASS: RAM test, 131072k bytes found.
INFO: BBR tests beginning.
PASS: BBR test, 512k bytes found.
INFO: Self tests complete
INFO: Downloading switch software.
Force EPROM download (Y) ?
INFO: Initial download succeeded
INFO: Executing configuration script <boot.cfg>
INFO: Switch startup complete
The following table explains the types of messages that AT-8900 and AT-9900
switches generate during initial startup.
Type
Description
INFO
An action has been taken by the system.
PASS
A test has been completed successfully.
ERROR
An error message that a test has failed but the system continues to
operate.
FAIL
An error message that a fatal error condition has caused the system to halt
in an unrecoverable fashion.
The following table explains messages in the output of AT-8900 and AT-9900
switches.
Message
INFO: Self tests beginning.
INFO: RAM tests beginning
PASS: RAM test, 131072k
bytes found
ERROR: RAM test test-number.
Error address = address
For example:
ERROR: RAM test 5. Error
address = 00345678
INFO: BBR tests beginning
PASS: BBR test. Battery OK
ERROR: BBR Battery low
PASS: BBR test, 512k bytes
found
AT-8900, AT-9900, AT-9900s Series Switches
Description
Code loader tests are about to begin.
RAM tests are about to begin.
RAM test passed and the switch is using the indicated
amount of memory.
The given RAM test failed at the given address, which
means the memory system is faulty. The test repeats until
it passes. If the error continues, contact your authorised
distributor or reseller.
BBR battery tests are about to begin.
BBR battery tests passed.
BBR battery test failed, indicating that the battery is
running low. The BBR battery must be replaced. Contact
your authorised Allied Telesyn distributor or reseller.
BBR size/location test passed with the indicated amount of
BBR found.
Software Release 3.0.2