5 Repair
5.7.4 Replacing the axis-4 gearbox
Continued
2
3
Routing the cable package in the housing
1
2
Continues on next page
704
Action
Check the axis-3 cable protector.
Replace if damaged.
Note
If replaced, apply grease to the axis-3 cable pro-
tector before refitting.
Route the cable package through the lower arm
support and up into the housing.
CAUTION
Make sure that no cables or hoses are twisted or
strained. Reroute if necessary.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Slip the axis-4 cable protector over the cable
package.
© Copyright 2020-2022 ABB. All rights reserved.
Note
Grease: 3HAC029132-001
Plastic cable protector, axis 3:
3HAC064693-001
xx2000001568
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (3 pcs)
Tightening torque: 2.6 Nm
xx2000001552
Note
Plastic cable protector, axis 4:
3HAC064694-001:
xx2000001570