5 Repair
5.5.2 Replacing the housing and extender unit
Continued
2
3
Reconnecting the air hoses and Ethernet cabling (if equipped)
1
2
3
Continues on next page
406
Action
Refit the second semicircular bracket to the tubu-
lar.
Route the cablings.
Leave the CP/CS connectors and motor
connectors out from the tubular support,
and Ethernet connectors and air hoses out
from the process hub.
The air hoses are facing upside in the
semicircular bracket.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Reconnect the air hoses.
Note
See the number markings on the air hoses for
help to find the corresponding air hoses.
For robots with Ethernet cabling
Access the connector from the process hub and
reconnect the connector.
J1.C2
Tip
See the number markings on the connectors for
help to find the corresponding connector.
© Copyright 2020-2022 ABB. All rights reserved.
Note
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 2.6 Nm
xx2000001749
Note
xx2000001539
xx2000001540
Product manual - IRB 1300