7
Securing the cable package in the lower arm
1
Product manual - IRB 1300
3HAC070390-001 Revision: G
Action
Remove the tool and refit the plug screw.
For robots with protection type Clean Room
(option 3351-4)
Refit the plug screw with the rubber washer.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
© Copyright 2020-2022 ABB. All rights reserved.
5.5.3 Replacing the tubular and tilt unit
Note
Tightening torque: 3 Nm
For robots NOT with protection
type Clean Room
Plug screw: 3HAC078352-001
xx2000001609
For robots with protection type
Clean Room (option 3351-4)
Plug screw, Clean Room:
3HAC078351-001
Rubber sealing washer:
3HAC075325-001
xx2000002496
Note
Continues on next page
5 Repair
Continued
459