Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
For robots with protection class IP67 (option
3350-670)
For robots with protection type Clean Room
(option 3351-4)
For robots with protection type Foundry Plus
(option 3352-10)
Valid for cabling with rear interface
Check the gasket.
Replace if damaged.
Valid for cabling with rear interface
Refit the base bottom cover together with the base
adapter.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Secure the base to the foundation with the attach-
ment screws and washers.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Note
Gasket for base adapter:
3HAC067818-001
xx2000002510
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (8 pcs)
Tightening torque: 2.6 Nm
xx2000001642
Note
Attachment screws: M16x50, qual-
ity: 8.8.
Washers: 17 x 30 x 3, steel hard-
ness class 200HV.
Tightening Torque: 150 Nm±10
Nm.