4
5
6
Pulling out the cable package
1
2
Product manual - IRB 1300
3HAC070390-001 Revision: G
Action
Cut the cable straps.
Disconnect the connectors.
•
FB2
•
MP2
•
FB3
•
MP3
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
145.
© Copyright 2020-2022 ABB. All rights reserved.
5.7.3 Replacing the axis-3 gearbox
Note
xx2000001549
xx2000001550
xx2000001551
Note
Continues on next page
5 Repair
Continued
651