5 Repair
5.5.3 Replacing the tubular and tilt unit
Continued
4
5
6
Separating the cable package from the housing
1
2
Continues on next page
428
Action
Cut the cable strap.
Note
The motor cablings have another strap fixed. Al-
ways cut the strap that fixes the cable package
to the plate.
Disconnect the connectors.
•
MP4
•
FB4
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
145.
© Copyright 2020-2022 ABB. All rights reserved.
Note
xx2000001543
xx2000001544
xx2000001545
Note
Product manual - IRB 1300
3HAC070390-001 Revision: G