Action
Insert the male header of the motor connectors
to the connector plate.
Reconnect the connectors.
•
FB4
•
MP4
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Route and secure the cabling with a cable strap.
Note
The motor cablings have another strap fixed. Pay
attention to the location where the new strap to
be fixed, see the figure as a guidance.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Refit the connector plate.
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.6.4 Replacing the axis-4 motor
Continued
Note
xx2000001545
xx2000001544
xx2000001543
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 2.6 Nm
xx2000001542
Continues on next page