5 Repair
5.7.2 Replacing the axis-2 gearbox
Continued
4
Disconnecting the axis-6 motor connectors
1
2
3
4
Continues on next page
594
Action
Remove the connector plates.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
145.
Disconnect the connectors.
MP6
FB6
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
© Copyright 2020-2022 ABB. All rights reserved.
Note
xx2000001531
Note
xx2000001532
xx2000001533
Product manual - IRB 1300
3HAC070390-001 Revision: G