Protection
type
Foundry Plus
Clean room
Cleaning with water and steam
Instructions for rinsing with water
IRB 1300 with protection class IP67 (option) and with protection type Foundry Plus
can be cleaned by rinsing with water (water cleaner).
The following list defines the prerequisites:
I
Cables
Movable cables need to be able to move freely:
1
See
Cleaning methods on page 106
Product manual - IRB 1300
3HAC070390-001 Revision: G
Cleaning method
Vacuum
Wipe with cloth
cleaner
Yes
Yes. With light
cleaning deter-
gent or spirit.
Yes
Yes. With light
cleaning deter-
gent, spirit or
isopropyl alco-
hol.
Maximum water pressure at the nozzle: 700 kN/m
Fan jet nozzle should be used, min. 45° spread
Minimum distance from nozzle to encapsulation: 0.4 meters
Maximum flow: 20 liters/min
Typical tap water pressure and flow
Remove waste material, such as sand, dust and chips, if it prevents cable
movement.
Clean the cables if they have a crusty surface, for example from dry release
agents.
for exceptions.
© Copyright 2020-2022 ABB. All rights reserved.
4.3.1 Cleaning the IRB 1300
Rinse with water
Yes. It is highly re-
commended that
the water contains
a rust-prevention
solution.
No
1
2
I
4 Maintenance
Continued
High pressure water or
steam
No
No
I
(7 bar)
107