5 Repair
5.5.2 Replacing the housing and extender unit
Continued
3
4
Separating the cable package from the tubular
1
2
3
Continues on next page
368
Action
For robots with CP/CS cabling
Disconnect the connectors.
J1.C1
J1.C3
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
145.
Remove the first semicircular bracket that fixes
the cable package.
© Copyright 2020-2022 ABB. All rights reserved.
Note
xx2000001536
xx2000001537
Note
xx2000001748
Product manual - IRB 1300