ABB IRB 1300 Product Manual page 555

Hide thumbs Also See for IRB 1300:
Table of Contents

Advertisement

5
Refitting the motor
Use these procedures to refit the axis-5 motor.
Refitting the axis-5 motor
1
2
3
4
Product manual - IRB 1300
3HAC070390-001 Revision: G
Action
Carefully lift out the motor.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
Orient the motor correctly and fit it into the tubular.
Refit the screws and washers.
Note
Do not tighten the screws yet.
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.6.5 Replacing the axis-5 motor
Continued
Note
xx2000001597
Note
Motor orientation: orient the motor
according to the figure below, in
regard to the encircled motor con-
nector.
xx2000001598
Screw: M5x16 12.9 Lafre
2C2B/FC6.9 (4 pcs)
xx2000001596
Continues on next page
555

Hide quick links:

Advertisement

Table of Contents
loading