07/11/02 09:17:55 61TA0000_110_0350
Fuel Supply System
DTC Troubleshooting (cont'd)
15. Connect fuel tank unit 4P connector terminal No. 1
to body ground with a jumper wire.
*03
16. Check for continuity between gauge control
module 32P connector terminal No. 27 and body
ground.
*04
Is there continuity?
YES
NO
control module (signal line) and the fuel gauge
sending unit, then go to step 27.
11-350
FUEL TANK UNIT 4P CONNECTOR
SIGNAL (PUR)
JUMPER WIRE
Wire side of female terminals
GAUGE CONTROL MODULE 32P CONNECTOR
SIGNAL (PUR)
Wire side of female terminals
Remove the jumper wire, then go to step 18.
Repair open in the wire between the gauge
17. Turn the ignition switch to LOCK (0).
18. Remove the fuel tank unit (see page 11-378).
19. Test the fuel gauge sending unit (see page 11-381).
Is the f uel gauge sending unit OK ?
YES
Go to step 20.
NO
Replace the fuel gauge sending unit (see page
11-377), then go to step 26.
20. Connect the fuel tank unit 4P connector.
21. Reconnect the gauge control module 32P connector.
22. Turn the ignition switch to ON (II).
23. Clear the DTC with the HDS.
24. Set the float (A) to the F position.
A
F
6.1 in.
(155.2 mm )
25. Check the fuel gauge.
Does the gauge move to the f ull position?
YES
Go to step 33.
NO
Replace the gauge control module (see page
22-332), then go to step 26.
*05