Toyota Celica 2005 Repair Manual page 1843

Hide thumbs Also See for Celica 2005:
Table of Contents

Advertisement

AX−10
2005 CELICA (RM1131U)
AUTOMATIC TRANSAXLE (U240E)
VALVE BODY ASSEMBLY
ON−VEHICLE REPAIR
1.
2.
3.
NOTICE:
Some fluid will remain in the oil pan.
Remove the 18 bolts, and carefully remove the oil pan assem-
bly. Discard the gasket.
D07261
4.
Remove the magnets and use them to collect any steel chips.
Look carefully at the chips and particles in the pan and on the
magnet to anticipate what type of wear you will find in the trans-
axle.
Steel (magnetic)...bearing, gear and plate wear
Brass (non−magnetic)... bushing wear
AT0103
5.
(a)
(b)
D05879
6.
7.
Remove the bolt and lock plate, and remove the ATF tempera-
ture sensor.
8.
D02934
VALVE BODY ASSEMBLY
REMOVE LH ENGINE UNDER COVER
REMOVE DRAIN PLUG AND DRAIN ATF
REMOVE OIL PAN AND GASKET
EXAMINE PARTICLES IN OIL PAN
REMOVE OIL STRAINER
Remove the 3 bolts and oil strainer.
Remove the O−ring.
DISCONNECT 5 SHIFT SOLENOID VALVE CONNEC-
TORS
REMOVE ATF TEMPERATURE SENSOR
SEPARATE WIRE HARNESS FROM 2 CLAMPS
1842