SR−28
Vane Pump Shaft
Height
Length
2005 CELICA (RM1131U)
STEERING
Bushing
Front Housing
F09875
Thickness
N00372
Feeler Gauge
R10282
POWER STEERING VANE PUMP
INSPECTION
1.
MEASURE OIL CLEARANCE BETWEEN VANE PUMP
SHAFT AND BUSHING
Using a micrometer and a caliper gauge, measure the oil clear-
ance.
Standard clearance:
0.021 − 0.043 mm (0.0008 − 0.0017 in.)
Maximum clearance: 0.07 mm (0.0028 in.)
If it is more than the maximum, replace the front housing and
vane pump shaft.
2.
INSPECT VANE PUMP ROTOR AND VANE PLATES
(a)
Using a micrometer, measure the height, thickness and
length of the 10 vane plates.
Minimum height: 7.6 mm (0.299 in.)
Minimum thickness: 1.405 mm (0.0553 in.)
Minimum length: 11.993 mm (0.4722 in.)
(b)
Using a feeler gauge, measure the clearance between
the vane pump rotor groove and vane plate.
Maximum clearance: 0.03 mm (0.0012 in.)