Ohmmeter
Ohmmeter
Air
E
Air
E
F
2005 CELICA (RM1131U)
INSPECTION
Continuity
INSPECT VSV
(a)
If there is no continuity, replace the VSV.
B09588
(b)
No Continuity
If there is continuity, replace the VSV.
B09589
(c)
G
B09590
If operation is not as specified, replace the VSV.
Battery
B09591
SFI
−
VSV FOR INTAKE AIR CONTROL VALVE
Inspect the VSV for open circuit.
Using an ohmmeter, check that there is no continuity be-
tween the terminals.
Resistance: 37 − 44 Ω at 20°C (68°F)
Inspect the VSV for ground.
Using an ohmmeter, check that there is no continuity be-
tween each terminal and the body.
Inspect the VSV operation.
(1)
Check that air flows from ports E to G.
(2)
Apply battery positive voltage across the terminals.
(3)
Check that air flows from ports E to F.
1579
SF−59
SF0PM−14