CO−12
2005 CELICA (RM1131U)
COOLING
RADIATOR
RADIATOR
ON−VEHICLE CLEANING
INSPECT FINS FOR BLOCKAGE
If fins are clogged, wash them with water or a steam cleaner and
dry with compressed air.
NOTICE:
If the distance between the steam cleaner and the
S
core is too close, there is a possibility of damaging
B14807
the fin, so keep the following injection distance.
Injection Pressure
2,942 − 4,903 kpa
(30 − 50 kg/cm
4,903 − 7,845 kpa
(50 − 80 kg/cm
If the fins are bent, straighten them with a screwdriver
S
or pliers.
Never apply water directly onto the electronic compo-
S
nents.
1612
2,
427 −711 psi)
2,
711 − 1,138 psi)
CO1B0−05
Injection Distance
300 mm (11.811 in)
500 mm (19.685 in)