SROS Command Line Interface Reference Guide
lldp [minimum-transmit-interval l reinitialization-delay l
transmit-interval l ttl-multiplier] <numeric value>
Use the lldp command to configure global settings that control the way LLDP functions.
Syntax Description
minimum-transmit-interval
reinitialization-delay
transmit-interval
ttl-multiplier
<numeric value>
Default Values
By default, minimum-transmit-interval = 2 seconds (valid range: 1 through 8192); reinitialization-delay =
2 seconds (valid range 1 through 10); transmit-interval = 30 seconds (valid range 5 through 32,768); and
ttl-multiplier = 4 (valid range 2 through 10).
Functional Notes
Once a device receives data from a neighboring device in an LLDP frame, it will retain that data for a
limited amount of time. This amount of time is called time-to-live, and it is part of the data in the LLDP
frame. The time-to-live transmitted in the LLDP frame is equal to the transmit-interval multiplied by the
ttl-multiplier.
Usage Examples
The following example sets the LLDP minimum-transmit-interval to 10 seconds:
ProCurve(config)#lldp minimum-transmit-interval 10
The following example sets the LLDP reinitialization-delay to 5 seconds:
ProCurve(config)#lldp reinitialization-delay 5
The following example sets the LLDP transmit-interval to 15 seconds:
ProCurve(config)#lldp transmit-interval 15
The following example sets the LLDP ttl-multiplier to 2 and the time-to-live for all LLDP frames transmitted
from this unit to 30 seconds;
ProCurve(config)#lldp transmit-interval 15
ProCurve(config)#lldp ttl-multiplier 2
5991-2114
Defines the minimum amount of time between transmission of LLDP frames
(in seconds).
Minimum amount of time to delay after LLDP is disabled on a port before
allowing transmission of additional LLDP frames on that port (in seconds).
Defines the delay between LLDP frame transmission attempts during
normal operation (in seconds).
Defines the multiplier to be applied to the transmit interval to compute the
time-to-live for data sent in an LLDP frame.
Specifies the interval, delay, or multiplier.
© Copyright 2007 Hewlett-Packard Development Company, L.P.
Global Configuration Mode Command Set