SROS Command Line Interface Reference Guide
test-pattern [clear | errors | insert | ones | p215 | p220 | p511 | qrss |
zeros]
Use the test-pattern command to activate the built-in pattern generator and begin sending the specified
test pattern. This pattern generation can be used to verify a data path when used in conjunction with an
active loopback. Use the no form of this command to cease pattern generation.
Syntax Description
clear
Clears the test pattern error count. Display the error count using the errors keyword.
errors
Displays the test pattern error count.
insert
Inserts an error into the currently active test pattern. Display the error count using the
errors keyword.
ones
Generates a test pattern of continuous ones.
p215
Generates a pseudorandom test pattern based on a 15-bit shift register.
p220
Generates a pseudorandom test pattern based on a 20-bit shift register.
p511
Generates a test pattern of repeating ones and zeros.
qrss
Generates a test pattern of random ones and zeros.
zeros
Generates a test pattern of continous zeros.
Default Values
No defaults necessary for this command.
Usage Examples
The following example activates the pattern generator for a stream of continuous ones:
ProCurve(config)#interface e1 1/1
ProCurve(config-e1 1/1)#test-pattern ones
5991-2114
© Copyright 2007 Hewlett-Packard Development Company, L.P.
E1 Interface Configuration Command Set
614