SROS Command Line Interface Reference Guide
line-length <value>
Use the line-length command to set the line build out (in feet or dB) for the DSX-1 interface. Use the no
form of this command to return to the default value.
Syntax Description
<value>
Default Values
By default, the line build out is set to 0 feet.
Functional Notes
The line-length value represents the physical distance between DSX equipment (measured in cable
length). Based on this setting, the SROS device increases signal strength to compensate for the distance
the signal must travel. Valid distance ranges are listed below:
•
0 to 133 feet
•
134 to 265 feet
•
266 to 399 feet
•
400 to 533 feet
•
534 to 655 feet
Use the -7.5 dB setting for maximum signal attenuation.
Usage Examples
The following example configures the DSX-1 interface line-length for 300 feet:
ProCurve(config)#interface t1 1/2
ProCurve(config-t1 1/2)#line-length 300
5991-2114
Configures the line build out for the DSX-1 interface.
Valid options include: -7.5 dB or <0 to 655> feet.