SROS Command Line Interface Reference Guide
coding [ami | hdb3]
Use the coding command to configure the line coding for the G.703 physical interface. This setting must
match the line coding supplied on the circuit by the PBX.
Syntax Description
ami
hdb3
Default Values
By default, all E1 interfaces are configured with HDB3 line coding.
Functional Notes
The line coding configured in the unit must match the line coding of the E1 circuit. A mismatch will result in
line errors (e.g., BPVs).
Usage Examples
The following example configures the G.703 interface for AMI line coding:
ProCurve(config)#interface e1 1/2
ProCurve(config-e1 1/2)#coding ami
5991-2114
Configures the line coding for alternate mark inversion (AMI).
Configures the line coding for high-density bipolar 3 (HDB3).
© Copyright 2007 Hewlett-Packard Development Company, L.P.
G.703 Interface Configuration Command set
679