Entering The Management Software Commands; Figure 145: Show System Command - Allied Telesis SwitchBlade x3112 Installation Manual

Access edge chassis switch
Table of Contents

Advertisement

2. Connect the other end of the cable to an RS-232 port on a terminal or
3. Configure the VT-100 terminal or terminal emulation program as
4. Press Enter. You are prompted for a user name and password.
5. Enter the default user name and password. They are "manager" and
Entering the
To confirm the operations of the chassis with the commands in the
management software, perform the following procedure:
Management
Software
1. Enter the SHOW SYSTEM command to display the software version
Commands
SHOW SYSTEM
--- System Information ----------------------------------------------
System Date.................. 2013-07-2
System Uptime................ 2 days, 14 hours, 27 minutes, 18 seconds
Software
Version.................. 17.0.0
Options ................. Customer-Release Build
Created ................. Tue 07/21/2012 at 1:25 PM
Boot From ................... preferred
Download from Www.Somanuals.com. All Manuals Search And Download.
personal computer with a terminal emulation program.
follows:
Baud rate: 115,200 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
"friend" (without the quotes), respectively
Note
User names and passwords are case sensitive.
The local management session starts and the command line interface
(CLI) prompt is displayed.
number of the management software on the control card, as shown in
Figure 145.
Figure 145. SHOW SYSTEM Command
SwitchBlade x3112 Installation Guide
Software Version
Number
193

Advertisement

Table of Contents
loading

Table of Contents