Yes- Resume normal operation
No- Go to Step 5
5. Inspect the Closer Module parts for damage. Replace any parts that
are worn or damaged.
This clears the fault
Yes- Return to normal operation
No- Go to Step 6
6. Replace the cables from the motor to the Main Control Board. Refer
to
GP 6.24
for cable identification.
This clears the fault
Yes- Resume normal operation
No- Go to Step 7
7. Replace Main Control Board B (REP 11.3)
This clears the fault
Yes- Resume normal operation
No- Escalate to second level
GBC eWire
GP 6.6

SOLENOID CHECKS

GP 6.6.1
Check Solenoids L1, L2, L3, and L4
Locate Solenoids L1, L2, L3, and L4:
Raise the lid by lifting the release handle
Insert a cheater into the Lid Interlock.
Solenoid L1, diverter solenoid, is located on the rear of the Lower
Transport Assembly. Refer to PL 5.3.
Solenoids L2, L3, and L4 are located on the top of the Upper
Transport Assembly. Refer to PL 5.3.
Moving Parts, keep hands clear of moving parts when
the Interlock Cheater is inserted. See Section 0, page
vii for other languages.
1. Do GP 6.3.4
SOLENOIDS Procedure
Solenoid L1, L2, L3, and/or L4
The diverter gate should rise and fall when L1 is cycled.
The corresponding rollers should rise and fall when L2, L3,
and L4 are cycled.
L2: Nip Rollers N2
o
01/26/2018
6-51