RAP 5.2
J371- S38 HOLDER POSITION ELEMENT TIMEOUT
J371 is triggered if it takes longer than specified time for the Holder to
reach S38 Holder at Element position sensor
1.
Do GP 6.4 to check S38 Holder Element position sensor
This clears the fault
Yes- Return to normal operation;
No- Go to Step 2
2. Check the Condition of the Holder linear drive belt- Front and Rear
(PL 5.21)
The timing belt is in good condition. There are no missing teeth
and the belt is not frayed
Yes- Go to Step 3;
No- Replace the damaged timing belt (REP 8.11, 8.12) and resume
operation
3. Check the tension of the Holder linear drive belt tension- Front and
Rear (ADJ 1.6)
The tension of the timing belts is good
Yes- Go to Step 4;
No- Do to ADJ 1.6 to set the belt tension and resume operation
4. Visually check if the rollers of the Holder are centered in the cam
tracks.
The rollers are centered in the cam tracks
Yes- Go to Step 5;
No- Loosen the cam track assembly and bring the roller inside the
cam track. Resume operation
GBC eWire
5. Check if the set screws on all the six pulleys associated with the
Holder linear drive are tight
The set screws are tight
Yes- Go to Step 6;
No- Tighten the loose set screw(s) and resume operation
6. Manually move the Holder linear mechanism and watch if the sheet
metal feature blocks/unblocks S38 Holder Stack position sensor.
The sensor is blocked/unblocked properly
Yes- Go to Step 7;
No- Escalate to second level