REP 3.14.1 Element Detect at Knife Sensor Replacement S21

PARTS LIST ON PL 5.11
Use this procedure to remove and install the Sensor for Element Detect at
Knife, S21.
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 3.15
Knife Module Replacement
4. Remove the Bottom Cover by removing the M3 Screws (2)
Repairs/Adjustments
to remove the Knife Module
5. Remove the sensor wires connector at the header.
6. Remove the M2 Screw from the underside of the Sensor Mounting
Block.
7. Remove the Sensor Mounting Block by pulling up on the block.
Remove the Sensor by sliding it out of the Sensor Mounting Block.